Model No.︰-
Brand Name︰hirschmann switch
Country of Origin︰-
Unit Price︰US $ 100 / pc
Minimum Order︰1 pc
Exchange disabled learning (hub function), independent VLAN learning, fast aging, static unicast/multicast address entries, QoS/port priority (802.1D/p), TOS/DSCP priority, egress broadcast limiter for each port, traffic control (802.3X), VLAN (802.1Q), IGMP Snooping/Querier (v1/v2/v3)
Redundant HIPER Ring (Manager), HIPER Ring (Ring Switch), Media Redundancy Protocol (MRP) (IEC62439-2), Redundant Network Coupling RSTP 802.1D-2004 (IEC62439-1)、RSTP Guards、RSTP over MRP
Manage TFTP, LLDP (802.1AB), V.24, HTTP, traps SNMP v1/v2/v3、Telnet
Diagnosis management address conflict detection, address relearning detection, signal connection, device status indication LED、Syslog、 Duplex mismatch detection RMON(1、2、3、9)、 Port mirroring 1:1, port mirroring 8:1, system information, cold start, SFP management, self check of switch dump
to configure AutoConfiguration Adapter ACA11 Limited Support (RS20/30/40, MS20/30), Automatic Configuration Undo (roll-back), Configuration Fingerprint, BOOTP/DHCP Client with Auto-Configuration, AutoConfiguration Adapter ACA21/22 (USB), HiDiscovery, DHCP Relay with option 82, command-line interface (CLI), full-featured MIB support, web-based management, context sensitive help
Security based on IP port security, MAC based port security, VLAN restricted management access, SNMP logging, local user management, password change upon first login
Time synchronization SNTP client, SNTP server
Industrial profiles EtherNet/IP protocol, PROFINET IO protocol
Various manual cable crossings
Pre-set standards
environmental condition
Working temperature 0-+60 ° C
Storage/transportation temperature -40-+70 ° C
Relative humidity (non condensing) 10-95%
mechanical structure
Dimensions (W x H x D) 74mm x 131mm x 111mm
Weight 410 grams
Install DIN rail
Protection level IP20
mechanical stability
IEC 60068-2-6 Vibration 1mm, 2Hz-13.2Hz, 90 minutes; 0.7 grams, 13.2 hertz -100 hertz, 90 minutes; 3.5 millimeters, 3 Hz-9 Hz, 10 cycles, 1 octave band/minute; 1 g,9 Hz-150 Hz, 10 cycles, 1 octave per minute
IEC 60068-2-27 Impact 15 g, 11 ms duration, 18 impacts
EMC anti-interference capability
EN 61000-4-2 Electrostatic Discharge (ESD) 6 kV Contact Discharge, 8 kV Air Discharge
EN 61000-4-3 Electromagnetic Field 10 V/m (80-1000 MHz)
EN 61000-4-4 Fast Transient (Burst) 2 kV Power Line, 1 kV Data Line
EN 61000-4-5 Surge Voltage Power Line: 2 kV (Line/Ground), 1 kV (Line/Line), 1 kV Data Line
EN 61000-4-6 Conducted Immunity 3 V (10 kHz-150 kHz), 10 V (150 kHz-80 MHz)
EMC emission immunity
EN 55032 EN 55032 Class A
FCC CFR47 Part 15 FCC 47CFR Part 15, Class A
approval
Basic standards CE, FCC, EN61131
Industrial control equipment security cUL 508
Dangerous Place cULus ISA12.12.01 class1 div.2 (cUL 1604 class1 div.2)